FMU Manipulation Toolbox includes built-in checkers (FMI-2 and FMI-3). You can also write your own custom checkers.

  • OperationGenericCheck validates modelDescription.xml against the official FMI XSD schema and reports every violation.
  • OperationSemanticCheck checks the rules of the standard that the schema cannot express (FMI-2.0.5 §2.2.7–2.2.8, FMI-3.0.2 §2.4.7–2.4.8). Each message cites the section of the standard:
    • variable names (and FMI-3 aliases) are unique; FMI-3 value references are unique;
    • allowed combinations of causality and variability; only Real / Float32 / Float64 variables can be continuous;
    • allowed values of initial, and presence or absence of a start value;
    • derivative attributes and <ModelStructure> entries refer to existing variables;
    • <Outputs> / <Output> lists exactly the outputs; state derivatives have a derivative attribute;
    • <InitialUnknowns> / <InitialUnknown> lists the outputs with initial="calculated" or "approx" (clocks and clocked variables excepted, as the Reference FMUs do), and no output with initial="exact".
  • OperationLsBusCheck checks the rules of FMI-LS-BUS, for an FMU that declares it.
  • OperationLsXcpCheck checks the rules of FMI-LS-XCP 1.0.0, for an FMU that declares it (manifest extra/org.fmi-standard.fmi-ls-xcp/fmi-ls-manifest.xml):
    • the manifest is valid against the XSD of FMI-LS-XCP;
    • the A2L file of each interface exists, in the directory of the manifest (source code FMU) or in at least one of its platform directories, and does not use /include; an A2L file for a platform without binaries is a warning;
    • each interface has containsXCPService or supportsDirectMemoryAccess;
    • each Variable refers to an existing scalar variable of the type of its role (Boolean, UInt16 in FMI-3 or Integer in FMI-2, String), declared as a fixed structuralParameter (FMI-3), a fixed parameter, a constant output or a fixed or tunable calculatedParameter; a variable is used once, a role once per interface.
  • OperationLsRefCheck checks the reference material of FMI-LS-REF, for an FMU that declares it (manifest extra/org.fmi-standard.fmi-ls-ref/fmi-ls-manifest.xml), and replays its experiments to compare the results with the references: see Validation of the results (FMI-LS-REF).

With fmutool -check, any error logged by a checker makes the command exit with status 7.

Running the Checker

fmutool -input my_model.fmu -check

In fmutool-gui, click the Check FMU button after loading an FMU.

from fmu_manipulation_toolbox.operations import FMU
from fmu_manipulation_toolbox.checker import OperationGenericCheck

fmu = FMU("my_model.fmu")
check = OperationGenericCheck()
fmu.apply_operation(check)

if check.compliant_with_version:
    print(f"FMU is compliant with FMI-{check.compliant_with_version[0]}")
else:
    print("FMU is NOT compliant")

Validation of the results (FMI-LS-REF)

FMI-LS-REF (1.0.0-alpha.1, a draft) lists the files related to an FMU in its manifest. The experiment files (role experiment, type application/x-ma-hs-experiments) follow the draft MA-HS-Experiments: each TransientExperiment gives its start and stop times, its step size, and its parameters (SSV file), stimuli and references (CSV files). The Reference FMUs give instead the output of their default experiment (role result, a CSV file).

Static checks

  • The manifest and the experiment files are valid against their XSD (shipped with the toolbox). A missing or different fmi-ls-description is a warning (the Reference FMUs have none).
  • A related file that is not in the FMU (missing file, absolute URI, relative URI leaving the FMU) is a warning. The relative URIs may hold .. while they stay inside the FMU (e.g. ../../resources/stimuli.csv).
  • Experiments: startTime before stopTime, a positive stepSize. The files of an experiment that is replayed must be in the FMU (error); the stimuli and references of a type other than text/csv, the parameters of a type other than application/x-ssp-parameter-set, are not supported (warning, the experiment is not replayed).
  • The columns of the stimuli are input variables, those of the references output variables; the parameters of the SSV file are parameter or structuralParameter variables, or input variables with a start value. A result file of the Reference FMUs may have columns that are not outputs of the FMU, or binaries: they are ignored (warning).

Replay and comparison

The experiments of sub-role smoke-test (the default) and validation, and the result files, are replayed on the host platform with the runtime of the FMU Container: the FMU is embedded in a temporary FMI-3 container, then simulated. Each experiment is simulated in a dedicated process: a crash of the FMU (e.g. a segmentation fault) or a simulation that does not end within 60 s (-ref-timeout) fails this experiment only (error, with the signal or the exit code of the process), the check and the other experiments go on.

  • Times: those of the experiment, else those of the DefaultExperiment of the FMU, else the first and last instants of the references. Without stepSize, the step size is the stepSize of the DefaultExperiment of the FMU, else it is deduced from the FMU as fmucontainer does. The tolerance of the experiment is not used.
  • Stimuli are interpolated at each communication point: linearly for the continuous real inputs, previous value for the others. The outputs are recorded at each communication point, after the stimuli of this instant.
  • Comparison at the instants of the references, the simulation being interpolated as the stimuli: a number (booleans as 0/1) matches when |simulated - reference| <= atol + rtol * |reference|, with rtol = 1e-3 and atol = 1e-6 by default (-ref-rtol, -ref-atol, or Selected Check in fmutool-gui); a string must be equal. At an event of the references (two rows with the same time), the value after the event is compared. Each output that differs is an error, with the first instant of the difference.
  • An experiment without references is simulated only. A simulation that fails, crashes or exceeds its time limit is an error.
  • An FMU may terminate the simulation (terminateSimulation): the simulation ends at the time reached, which is normal. The references after it are not compared (warning).
  • Not replayed (warning): the experiments of sub-role uncertainty-analysis, when the runtime of the container or the binary of the FMU is not available for the host platform, and the experiments with a stimulus on a Boolean input of an FMI-2 FMU (the FMI-3 container cannot expose it).

The CSV files follow the convention of the FMI cross-check: comma separator, a first column time, one column per variable named after it:

time,Float64_continuous_input,Int32_input,Boolean_input
0,0,0,false
1,10,5,true
2,0,7,false

Writing a Custom Checker

A checker is a class derived from OperationAbstract. Override the callback methods to inspect FMU attributes and ports:

import logging
from fmu_manipulation_toolbox.operations import OperationAbstract, ModelVariable

logger = logging.getLogger("fmu_manipulation_toolbox")


class CheckNamingConvention(OperationAbstract):
    """Check that all port names use snake_case."""

    def __repr__(self):
        return "Naming convention checker"

    def port_attrs(self, fmu_port: ModelVariable) -> int:
        name = fmu_port["name"]
        if name != name.lower():
            logger.warning(f"Port '{name}' is not snake_case")
        return 0

Save this file (e.g., my_checkers.py) anywhere on your system.

Registering Custom Checkers

From a Python file

Use add_from_file to load checkers at runtime before running fmutool:

from fmu_manipulation_toolbox.checker import add_from_file

add_from_file("path/to/my_checkers.py")

All classes that directly subclass OperationAbstract in the file will be automatically registered and executed during checks.

Via entry points

You can also register checkers as Python package entry points using the fmu_manipulation_toolbox.checkers group in your setup.py or pyproject.toml:

[project.entry-points."fmu_manipulation_toolbox.checkers"]
my_checker = "my_package:get_checker_class"

A checker that cannot be imported, from a file or through an entry point, is reported as an error and skipped: the other checkers still run. This is the case of a checker written for version 1.x that still imports FMUPort, removed in 2.0: replace it by ModelVariable (see Writing Custom Operations).