Container with LS-XCP enabled FMUs¶
FMI-LS-XCP describes how an FMU gives access to its internal variables to a measurement and calibration tool (MCD tool, XCP master): the FMU declares in its manifest extra/org.fmi-standard.fmi-ls-xcp/fmi-ls-manifest.xml one or more interfaces, each one with an A2L file. An interface either runs its own XCP slave in the FMU (containsXCPService), listening on a TCP and/or UDP port, or allows an external XCP slave to access the memory of the FMU (supportsDirectMemoryAccess).
Inside a container, the container is the importer of its embedded FMUs: fmucontainer forwards the XCP services of the embedded FMUs. The MCD tool connects to each of them, with the A2L files given by the container.
What is supported¶
| Topic | Support |
|---|---|
| Version | FMI-LS-XCP 1.0.0, embedded FMUs FMI-2 and FMI-3, containers FMI-2 and FMI-3 |
XCP service in the FMU (containsXCPService) | Forwarded: declared by the container, A2L files copied, configuration exposed |
Direct memory access only (supportsDirectMemoryAccess) | Not forwarded, with a warning: the container provides no XCP slave, and the addresses of the A2L file are relative to the binary of the FMU |
| Several services | One per interface of each embedded FMU: the MCD tool connects to each of them |
| Port conflicts | Two services on the same port of the same protocol are refused when the container is built |
What the container does¶
For each forwarded interface, the container:
- declares an
Interfacein its own manifest, with the definition<fmu id>/<definition>(the<fmu id>is the name of the embedded FMU, without.fmu, in lowercase); - copies the A2L files in
extra/org.fmi-standard.fmi-ls-xcp/<platform>/<fmu id>/, for the platforms of the container; - exposes the variables that configure the service (roles
XCPServiceTCPEnable,XCPServiceTCPPort,XCPServiceTCPListenAddressand their UDP counterparts), as<fmu id>.<variable>, whatever theauto_*options. The importer of the container can then enable or disable each service and choose its port and its listen address.
A variable already used by a rule of the description (for instance exposed under another name) keeps that rule: the manifest of the container refers to the name it is exposed with.
Some variables are not exposed (they keep their start value, or the one given in the description):
- the variables that only announce the configuration (
constantoutput,calculatedParameter): the importer cannot change it; - the variables whose type the container cannot expose for their role: an FMI-3
UInt16port orBooleanin an FMI-2 container, an FMI-2Integerport in an FMI-3 container (it would be anInt32, FMI-LS-XCP needs aUInt16). A warning is issued.
Ports¶
Each XCP service listens on a port, which must be unique on the machine. When the container is built, the port of each enabled service is, by priority:
- the start value of its variable given in the description (
startblock of a JSON file); - the start value of its variable in the embedded FMU;
- the port of the
IF_DATA XCPof its A2L file.
Two services that use the same port of the same protocol are refused, whatever their listen addresses. This is the case of an FMU embedded several times: set another port for one of its instances.
{
"name": "two_ecus.fmu",
"fmu": ["ecu.fmu", "ecu-1.fmu"],
"path": {"ecu-1.fmu": "ecu.fmu"},
"start": [["ecu-1.fmu", "XCP.TCP.Port", "5556"]]
}
A service disabled by its Enable variable is not checked. When the port of a service is unknown, a warning is issued.
Note
The ports are checked with the values known when the container is built. The importer of the container may change them through the exposed variables: it is then responsible for their consistency, and for the port written in the A2L files given to the MCD tool, as FMI-LS-XCP requires.
Configuration Mode¶
An FMI-3 FMU usually declares its configuration variables as structural parameters: they can only be set in Configuration Mode, and the FMU starts its XCP service when it leaves it. The container handles it:
- an FMI-3 container exposes them as structural parameters. When its importer puts it in Configuration Mode, the container puts these FMUs in Configuration Mode too, and forwards the values;
- otherwise (FMI-2 container, where they are exposed as parameters, or importer that does not use the Configuration Mode), the container configures these FMUs itself before their initialization, with the values set by its importer.
An FMI-2 FMU starts its XCP service in fmi2SetupExperiment: the container sets its parameters, and the values set by its importer, before calling it.
Checking an FMU¶